  Kernel driver g762
  ==================
  
  The GMT G762 Fan Speed PWM Controller is connected directly to a fan
  and performs closed-loop or open-loop control of the fan speed. Two
  modes - PWM or DC - are supported by the device.
  
  For additional information, a detailed datasheet is available at
  http://natisbad.org/NAS/ref/GMT_EDS-762_763-080710-0.2.pdf. sysfs
  bindings are described in Documentation/hwmon/sysfs-interface.
  
  The following entries are available to the user in a subdirectory of
  /sys/bus/i2c/drivers/g762/ to control the operation of the device.
  This can be done manually using the following entries but is usually
  done via a userland daemon like fancontrol.
  
  Note that those entries do not provide ways to setup the specific
  hardware characteristics of the system (reference clock, pulses per
  fan revolution, ...); Those can be modified via devicetree bindings
  documented in Documentation/devicetree/bindings/hwmon/g762.txt or
  using a specific platform_data structure in board initialization
  file (see include/linux/platform_data/g762.h).
  
    fan1_target: set desired fan speed. This only makes sense in closed-loop
              fan speed control (i.e. when pwm1_enable is set to 2).
  
    fan1_input: provide current fan rotation value in RPM as reported by
              the fan to the device.
  
    fan1_div: fan clock divisor. Supported value are 1, 2, 4 and 8.
  
    fan1_pulses: number of pulses per fan revolution. Supported values
              are 2 and 4.
  
    fan1_fault: reports fan failure, i.e. no transition on fan gear pin for
              about 0.7s (if the fan is not voluntarily set off).
  
    fan1_alarm: in closed-loop control mode, if fan RPM value is 25% out
              of the programmed value for over 6 seconds 'fan1_alarm' is
              set to 1.
  
    pwm1_enable: set current fan speed control mode i.e. 1 for manual fan
              speed control (open-loop) via pwm1 described below, 2 for
              automatic fan speed control (closed-loop) via fan1_target
              above.
  
    pwm1_mode: set or get fan driving mode: 1 for PWM mode, 0 for DC mode.
  
    pwm1: get or set PWM fan control value in open-loop mode. This is an
              integer value between 0 and 255. 0 stops the fan, 255 makes
              it run at full speed.
  
  Both in PWM mode ('pwm1_mode' set to 1) and DC mode ('pwm1_mode' set to 0),
  when current fan speed control mode is open-loop ('pwm1_enable' set to 1),
  the fan speed is programmed by setting a value between 0 and 255 via 'pwm1'
  entry (0 stops the fan, 255 makes it run at full speed). In closed-loop mode
  ('pwm1_enable' set to 2), the expected rotation speed in RPM can be passed to
  the chip via 'fan1_target'. In closed-loop mode, the target speed is compared
  with current speed (available via 'fan1_input') by the device and a feedback
  is performed to match that target value. The fan speed value is computed
  based on the parameters associated with the physical characteristics of the
  system: a reference clock source frequency, a number of pulses per fan
  revolution, etc.
  
  Note that the driver will update its values at most once per second.