6b13f685e
김민수
BSP 최초 추가
|
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
|
/*
*
* Generic internet FLOW.
*
*/
#ifndef _NET_FLOW_H
#define _NET_FLOW_H
#include <linux/socket.h>
#include <linux/in6.h>
#include <linux/atomic.h>
struct flowi_common {
int flowic_oif;
int flowic_iif;
__u32 flowic_mark;
__u8 flowic_tos;
__u8 flowic_scope;
__u8 flowic_proto;
__u8 flowic_flags;
#define FLOWI_FLAG_ANYSRC 0x01
#define FLOWI_FLAG_KNOWN_NH 0x02
__u32 flowic_secid;
};
union flowi_uli {
struct {
__be16 dport;
__be16 sport;
} ports;
struct {
__u8 type;
__u8 code;
} icmpt;
struct {
__le16 dport;
__le16 sport;
} dnports;
__be32 spi;
__be32 gre_key;
struct {
__u8 type;
} mht;
};
struct flowi4 {
struct flowi_common __fl_common;
#define flowi4_oif __fl_common.flowic_oif
#define flowi4_iif __fl_common.flowic_iif
#define flowi4_mark __fl_common.flowic_mark
#define flowi4_tos __fl_common.flowic_tos
#define flowi4_scope __fl_common.flowic_scope
#define flowi4_proto __fl_common.flowic_proto
#define flowi4_flags __fl_common.flowic_flags
#define flowi4_secid __fl_common.flowic_secid
/* (saddr,daddr) must be grouped, same order as in IP header */
__be32 saddr;
__be32 daddr;
union flowi_uli uli;
#define fl4_sport uli.ports.sport
#define fl4_dport uli.ports.dport
#define fl4_icmp_type uli.icmpt.type
#define fl4_icmp_code uli.icmpt.code
#define fl4_ipsec_spi uli.spi
#define fl4_mh_type uli.mht.type
#define fl4_gre_key uli.gre_key
} __attribute__((__aligned__(BITS_PER_LONG/8)));
static inline void flowi4_init_output(struct flowi4 *fl4, int oif,
__u32 mark, __u8 tos, __u8 scope,
__u8 proto, __u8 flags,
__be32 daddr, __be32 saddr,
__be16 dport, __be16 sport)
{
fl4->flowi4_oif = oif;
fl4->flowi4_iif = 0;
fl4->flowi4_mark = mark;
fl4->flowi4_tos = tos;
fl4->flowi4_scope = scope;
fl4->flowi4_proto = proto;
fl4->flowi4_flags = flags;
fl4->flowi4_secid = 0;
fl4->daddr = daddr;
fl4->saddr = saddr;
fl4->fl4_dport = dport;
fl4->fl4_sport = sport;
}
/* Reset some input parameters after previous lookup */
static inline void flowi4_update_output(struct flowi4 *fl4, int oif, __u8 tos,
__be32 daddr, __be32 saddr)
{
fl4->flowi4_oif = oif;
fl4->flowi4_tos = tos;
fl4->daddr = daddr;
fl4->saddr = saddr;
}
struct flowi6 {
struct flowi_common __fl_common;
#define flowi6_oif __fl_common.flowic_oif
#define flowi6_iif __fl_common.flowic_iif
#define flowi6_mark __fl_common.flowic_mark
#define flowi6_tos __fl_common.flowic_tos
#define flowi6_scope __fl_common.flowic_scope
#define flowi6_proto __fl_common.flowic_proto
#define flowi6_flags __fl_common.flowic_flags
#define flowi6_secid __fl_common.flowic_secid
struct in6_addr daddr;
struct in6_addr saddr;
__be32 flowlabel;
union flowi_uli uli;
#define fl6_sport uli.ports.sport
#define fl6_dport uli.ports.dport
#define fl6_icmp_type uli.icmpt.type
#define fl6_icmp_code uli.icmpt.code
#define fl6_ipsec_spi uli.spi
#define fl6_mh_type uli.mht.type
#define fl6_gre_key uli.gre_key
} __attribute__((__aligned__(BITS_PER_LONG/8)));
struct flowidn {
struct flowi_common __fl_common;
#define flowidn_oif __fl_common.flowic_oif
#define flowidn_iif __fl_common.flowic_iif
#define flowidn_mark __fl_common.flowic_mark
#define flowidn_scope __fl_common.flowic_scope
#define flowidn_proto __fl_common.flowic_proto
#define flowidn_flags __fl_common.flowic_flags
__le16 daddr;
__le16 saddr;
union flowi_uli uli;
#define fld_sport uli.ports.sport
#define fld_dport uli.ports.dport
} __attribute__((__aligned__(BITS_PER_LONG/8)));
struct flowi {
union {
struct flowi_common __fl_common;
struct flowi4 ip4;
struct flowi6 ip6;
struct flowidn dn;
} u;
#define flowi_oif u.__fl_common.flowic_oif
#define flowi_iif u.__fl_common.flowic_iif
#define flowi_mark u.__fl_common.flowic_mark
#define flowi_tos u.__fl_common.flowic_tos
#define flowi_scope u.__fl_common.flowic_scope
#define flowi_proto u.__fl_common.flowic_proto
#define flowi_flags u.__fl_common.flowic_flags
#define flowi_secid u.__fl_common.flowic_secid
} __attribute__((__aligned__(BITS_PER_LONG/8)));
static inline struct flowi *flowi4_to_flowi(struct flowi4 *fl4)
{
return container_of(fl4, struct flowi, u.ip4);
}
static inline struct flowi *flowi6_to_flowi(struct flowi6 *fl6)
{
return container_of(fl6, struct flowi, u.ip6);
}
static inline struct flowi *flowidn_to_flowi(struct flowidn *fldn)
{
return container_of(fldn, struct flowi, u.dn);
}
typedef unsigned long flow_compare_t;
static inline size_t flow_key_size(u16 family)
{
switch (family) {
case AF_INET:
BUILD_BUG_ON(sizeof(struct flowi4) % sizeof(flow_compare_t));
return sizeof(struct flowi4) / sizeof(flow_compare_t);
case AF_INET6:
BUILD_BUG_ON(sizeof(struct flowi6) % sizeof(flow_compare_t));
return sizeof(struct flowi6) / sizeof(flow_compare_t);
case AF_DECnet:
BUILD_BUG_ON(sizeof(struct flowidn) % sizeof(flow_compare_t));
return sizeof(struct flowidn) / sizeof(flow_compare_t);
}
return 0;
}
#define FLOW_DIR_IN 0
#define FLOW_DIR_OUT 1
#define FLOW_DIR_FWD 2
struct net;
struct sock;
struct flow_cache_ops;
struct flow_cache_object {
const struct flow_cache_ops *ops;
};
struct flow_cache_ops {
struct flow_cache_object *(*get)(struct flow_cache_object *);
int (*check)(struct flow_cache_object *);
void (*delete)(struct flow_cache_object *);
};
typedef struct flow_cache_object *(*flow_resolve_t)(
struct net *net, const struct flowi *key, u16 family,
u8 dir, struct flow_cache_object *oldobj, void *ctx);
struct flow_cache_object *flow_cache_lookup(struct net *net,
const struct flowi *key, u16 family,
u8 dir, flow_resolve_t resolver,
void *ctx);
void flow_cache_flush(void);
void flow_cache_flush_deferred(void);
extern atomic_t flow_cache_genid;
#endif
|