  Kernel driver max1668
  =====================
  
  Supported chips:
    * Maxim MAX1668, MAX1805 and MAX1989
      Prefix: 'max1668'
      Addresses scanned: I2C 0x18, 0x19, 0x1a, 0x29, 0x2a, 0x2b, 0x4c, 0x4d, 0x4e
      Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX1668-MAX1989.pdf
  
  Author:
      David George <david.george@ska.ac.za>
  
  Description
  -----------
  
  This driver implements support for the Maxim MAX1668, MAX1805 and MAX1989
  chips.
  
  The three devices are very similar, but the MAX1805 has a reduced feature
  set; only two remote temperature inputs vs the four avaible on the other
  two ICs.
  
  The driver is able to distinguish between the devices and creates sysfs
  entries as follows:
  
  MAX1805, MAX1668 and MAX1989:
  
  temp1_input     ro local (ambient) temperature
  temp1_max       rw local temperature maximum threshold for alarm
  temp1_max_alarm ro local temperature maximum threshold alarm
  temp1_min       rw local temperature minimum threshold for alarm
  temp1_min_alarm ro local temperature minimum threshold alarm
  temp2_input     ro remote temperature 1
  temp2_max       rw remote temperature 1 maximum threshold for alarm
  temp2_max_alarm ro remote temperature 1 maximum threshold alarm
  temp2_min       rw remote temperature 1 minimum threshold for alarm
  temp2_min_alarm ro remote temperature 1 minimum threshold alarm
  temp3_input     ro remote temperature 2
  temp3_max       rw remote temperature 2 maximum threshold for alarm
  temp3_max_alarm ro remote temperature 2 maximum threshold alarm
  temp3_min       rw remote temperature 2 minimum threshold for alarm
  temp3_min_alarm ro remote temperature 2 minimum threshold alarm
  
  MAX1668 and MAX1989 only:
  temp4_input     ro remote temperature 3
  temp4_max       rw remote temperature 3 maximum threshold for alarm
  temp4_max_alarm ro remote temperature 3 maximum threshold alarm
  temp4_min       rw remote temperature 3 minimum threshold for alarm
  temp4_min_alarm ro remote temperature 3 minimum threshold alarm
  temp5_input     ro remote temperature 4
  temp5_max       rw remote temperature 4 maximum threshold for alarm
  temp5_max_alarm ro remote temperature 4 maximum threshold alarm
  temp5_min       rw remote temperature 4 minimum threshold for alarm
  temp5_min_alarm ro remote temperature 4 minimum threshold alarm
  
  Module Parameters
  -----------------
  
  * read_only: int
    Set to non-zero if you wish to prevent write access to alarm thresholds.